NTPC Limited
(A Government of India Enterprise)
EXPRESSION OF INTEREST (EOI)
FOR
RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR
VARIOUS NTPC PLANTS
DOCUMENT NO.:
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 1
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 2
(ABRIDGED INVITATION FOR EXPRESSION OF INTEREST)
NTPC LIMITED
(A Govt. of India Enterprise)
CORPORATE CONTRACTS, NOIDA
INVITATION FOR EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOx EMISSION CONTROL SYSTEM FOR VARIOUS NTPC PLANTS
EOI No.: |
Date: 24/02/2016 |
NTPC invites EOI from reputed agencies (Boiler manufacturer and SCR / NOx emission control technology suppliers) in India and abroad.
EOI shall be received upto 1500 hrs (IST) on 25.03.2016.
For detailed EOI and documents, please visit at www.ntpctender.com or www.ntpc.co.in or may contact Manager
Tel. No.:
Fax No.:
Registered office: NTPC Bhawan, SCOPE Complex, 7, Institutional Area, Lodi Road, New
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 3
(DETAILED INVITATION FOR EXPRESSION OF INTEREST)
INVITATION FOR EXPRESSION OF INTEREST (EOI)
FOR
RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR
VARIOUS NTPC PLANTS
EOI No.: |
Date: 24/02/2016 |
1.0INTRODUCTION
NTPC invites Expression of Interest from reputed agencies (Boiler manufacturer and SCR / NOx emission control technology suppliers) in India and abroad who have experience in NOx emission control technology (i.e. SCR, SNCR, Low NOx firing/combustion system modification or any of its combination) and need it for retrofit in its various coal based thermal units.
2.0SCOPE OF WORK
The brief scope of work for Retrofitting of NOx Emission Control System for various NTPC plants would basically involve retrofitting of feasible technology like SCR, SNCR, Low NOx firing/combustion system modification or any of its combination for its various units to control the NOx emission as per the notification dated 8th December 2015 by Ministry of Environment, Forest and Climate Change.
3.0INTENT OF THE EXPRESSION OF INTEREST (EOI)
Through this EOI, NTPC intends to seek the willingness of reputed agencies to participate in various NOx control initiatives which NTPC intends to take in near future by suitably retrofitting its existing coal fired units and to collect past data from these agencies in respect of experience, financial, capability for NOx reduction with various technology,
4.0ELIGIBILITY
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 4
Agencies of repute who meet any of the following criteria are invited to submit their application for Expression of Interest (EOI):
(i)Manufacturer of Steam Generator of units of capacity of 200MW or above
(ii)Agencies who have supplied/executed contract for retrofitting jobs of NOx emission control operating at any one single power plant successfully for one years.
(iii)Indian agencies who have tie ups with foreign agencies who have the capabilities as at (i) or (ii) above.
(iv)Indian subsidiaries/ Indian Joint ventures/ Indian promoters of JV companies of foreign agencies who jointly meet the capabilities as at (i) or (ii) above.
5.0DOWNLOAD AND SUBMISSION OF EOI
Interested agencies may download the documents of EOI free of cost from www.ntpctender.com. The agencies shall submit their duly filled EOI through e- mail to itisur@ntpc.co.in on or before 25.03.2016 (1500 hrs (IST)).
6.0NTPC reserves the right to reject or accept any or all applications, cancel/withdraw the EOI process without assigning any reason whatsoever and in such case no applicant / intending applicant shall have any claim arising out of such action.
7.0Address for Communication
Manager (Contract
Distt. Gautam Budh Nagar, (UP), INDIA, Pin - 201301 Fax No.:
Tel. No.:
Websites: www.ntpctender.com or www.ntpc.co.in
CIN: L40101DL1975GOI007966
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 5
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 6
INSTRUCTIONS TO APPLICANTS
1.0INTRODUCTION
NTPC was incorporated in the year 1975, with the objective of planning, promoting and organizing an integrated development of Power Stations in India. With an installed capacity of above 45000 MW, NTPC is the largest power generating major in the country. NTPC designated as one of the Maharatna Public Sector Undertaking is poised to become a global giant and the mega power utility has ambitious plan to become 1,28,000 MW plus company by 2032. To realize its goal of becoming 1,28,000 MW Company by 2032, NTPC already has a long list of projects in pipeline.
Coal fired units under operation, installed after 31st Dec, 2003, are 31 in nos having different unit sizes (mostly 500 & 660 MW size). These have cumulative generation capacity of 15590 MW. For these NOx emission level is to brought down to 300 mg/Nm3.
Further, thirty
NTPC invites Expression of Interest from reputed agencies (Boiler manufacturer and SCR / NOx emission control technology suppliers) in India and abroad who have experience in NOx emission control technology (i.e. SCR, SNCR, Low NOx firing/combustion system modification or any of its combination) and need it for retrofit in its various coal based thermal units. Accordingly, ‘Retrofitting of NOx Emission Control System Package’ is
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 7
likely to be floated for installation of DeNOx system to meet the requirements as per new environment norms.
2.0SCOPE OF WORK:
The brief scope of work for Retrofitting of NOx Emission Control System for various NTPC plants would basically involve retrofitting of feasible technology like SCR, SNCR, Low NOx firing/combustion system modification or any of its combination for its various units to control the NOx emission as per the notification dated 8th December 2015 by Ministry of Environment, Forest and Climate Change. This retrofit work will need to be performed with in available space, infrastructure and other constraints in a professional manner.
Details of such NTPC, it’s JV/Subsidiaries owned coal fired units are as under:
NTPC owned operational Coal fired units installed before 31st Dec, 2003
Unit Capacity |
Units having capacity |
Units having capacity of |
|
(MW) |
smaller than 220MW |
500MW and above |
|
No. of units |
47 |
20 |
|
Total Capacity |
8185 |
10000 |
|
(MW) |
|||
|
|
NTPC owned operational Coal fired units installed after 31st Dec, 2003
Unit Capacity |
Units having capacity |
Units having capacity of |
|
(MW) |
smaller than 500MW |
500MW and above |
|
No. of units |
3 |
28 |
|
Total Capacity |
1190 |
14800 |
|
(MW) |
|||
|
|
NTPC/NTPC’s JV/ Subsidiaries owned, under construction Coal fired units
Unit Capacity |
Units having capacity |
Units having capacity of |
|
(MW) |
smaller than 500MW |
500MW and above |
|
No. of units |
8 |
29 |
|
Total Capacity |
1945 |
20240 |
|
(MW) |
|||
|
|
3.0INTENT OF THE EXPRESSION OF INTEREST (EOI)
Through this EOI, NTPC intends to seek the willingness of reputed agencies/boiler manufacturers etc who are willing to participate in various NOx control initiatives which NTPC intends to take in near future by suitably retrofitting its existing coal fired units and to collect past data from these vendors/manufacturers in respect of experience, financial, capability for NOx reduction with various technology,
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 8
‘Retrofitting of NOx Emission Control System Package’ is likely to be floated for installation of DeNOx system in various operational and under construction coal based units of NTPC, to meet the requirements as per new environment norms, as mentioned at 2.0 above or for the new power stations that NTPC may
This invitation for Expression of Interest is not intended for empanelment or pre- qualification of bidders. Separate NIT shall be floated by NTPC for Retrofitting of NOx Emission Control System Package for existing units and any of its forthcoming projects as and when required.
Further, NTPC reserves the right to include/ exclude any equipment/ system/ facility in the Scope of proposed Retrofitting of NOx Emission Control System for various NTPC plants.
4.0ELIGIBILITY
Agencies of repute who meet any of the following criteria are invited to submit their application for Expression of Interest (EOI):
(v)Manufacturer of Steam generator of units of capacity of 200MW or above
(vi)Agencies who have supplied/executed contract for retrofitting/ new jobs of NOx emission control system i.e. Combustion modification, SNCR or SCR system in past for pulverised coal based thermal power units of capacity 200MW or above and operating at any one single power plant successfully for one years.
(vii)Indian agencies who have tie ups with foreign Contractors who have the capabilities as at (i) or (ii) above.
(viii)Indian subsidiaries/ Indian Joint ventures/ Indian promoters of JV companies of foreign agencies who jointly meet the capabilities as at (i) or (ii) above.
5.0DOCUMENTS OF EOI
The EOI documents shall comprise of the following sections:
(i)
(ii)
(ii)
6.0Documents comprising the Application
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 9
The application of EOI shall comprise the following:
A)Form of Application: The form of application shall indicate willingness of agencies to participate in the appropriate
B)Schedules:
a.
b.
c.
d.
(i)Retrofitting the combustion system/staging of air etc.
(ii)Installation of SNCR system
(iii)Retrofitting the operating units by installing SCR system
(iv)Installing SCR system in new installations
(v)Any other technological intervenes /arrangements
e.
f.
g.
h.
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 10
7.0Submission of Application of EOI
The application of EOI shall be submitted in the following manner:
(i)The Form of Application shall be submitted on the letter head of the company.
(ii)The Schedules shall be submitted in MS word format in one single file.
(ii)The credentials/supporting documents shall be submitted in pdf file
format. (The applicants are advised to combine all credentials/supporting documents in single pdf file.)
The above mentioned documents shall be submitted through
8.0Deadline for submission of Application of EOI
The application of EOI must be submitted through
9.0Open House Discussion
NTPC at its discretion may conduct the open house discussion with the agencies who have submitted their EOI. The date and venue of conducting open house discussion shall be intimated later.
10.0EOI process will be subject to verification of all information submitted at the discretion of NTPC. NTPC reserves the right to reject or accept any or all applications, cancel/withdraw the EOI process without assigning any reason whatsoever and in such case no applicant / intending applicant shall have any claim arising out of such action.
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 11
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 12
FORM OF APPLICATION
(To be submitted on Company’s Letter Head)
Ref No. |
Date: |
Manager
NTPC Limited,6th Floor, Engineering Office Complex,
Distt. Gautam Budh Nagar
Uttar Pradesh, INDIA 201301
Dear Sir,
Sub: Expression of Interest (EOI) for “Retrofitting of NOx Emission Control System for various NTPC plants”.
We, the undersigned, express our interest for the subject EOI and declare the following:
(a)We are duly authorized to represent and act on behalf of _____________
(name of the firm).
(b)We have examined and have no reservations to the EOI document including Amendment No(s) & Clarification No(s)_________ (if any).
(c)With reference to your invitation for EOI dated _________, we are furnishing herewith all the required details as per the prescribed Schedules.
(d)We hereby express our willingness to participate in appropriate DeNox as and when NTPC invite the proposal for the same.
(e)NTPC and /or its authorized representatives are hereby authorized to conduct any inquiries or investigations to verify the statements, documents and information submitted in connection with this application, and to seek clarifications from our bankers and clients. This application will also serve as authorized on for any individual or authorized representative of any institution referred to in the supporting information, to provide such information deemed necessary and as requested by NTPC.
(f)NTPC and /or its authorized representatives may contact the following nodal persons for further information on any aspects of the application:
Name and designation of |
Address for |
Telephone |
|
contact Person |
Communication |
No |
ID |
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 13
(g)This application is made in the full understanding that:
1.Through this EOI, NTPC intends to only identify the probable vendors in India & abroad who have experience in supplying Nox control emission system i.e. Modification in combustion system, SCR & SNCR and also retrofitted the same in pulverised coal fired units and that this invitation for Expression of Interest is not intended for empanelment or pre- qualification of bidders. Further, intend to install SCR catalyst demo plant in order to get assessment of their catalyst for high ash Indian coal,
2.EOI process will be subject to verification of all information submitted at the discretion of NTPC.
3.NTPC reserves the right to reject or accept any or all applications, cancel the EOI process without any obligation to inform the applicant about the grounds of same.
(h)We declare that we have read and abide by the provisions of Fraud Prevention Policy of NTPC and submit the form of Acceptance of Fraud Prevention Policy duly filled as per NTPC’s format.
(i)The undersigned declare that the statements made and the information provided in the duly completed application are complete, true and correct in every detail.
Name :
In the Capacity of:
Signed
Duly authorized to sign the application for and on behalf of:
Date:
Place:
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 14
SCHEDULES
(SCHEDULES ARE TO BE FILLED UP AND SUBMITTED IN MS WORD FORMAT. All CREDENTIALS/SUPPORTING DOCUMENTS RELEVANT TO THE SCHEDULES ARE TO BE SUBMITTED PREFERABLY IN SINGLE PDF FILE. )
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 15
Schedule – 1
(Company Profile and Organization Structure)
Name of the Company:
Registered Address:
Contact Person & Designation:
Postal address for communication:
Telephone No.:
Fax No.:
Document regarding Organization Structure and Ownership are enclosed.
Schedule – 2
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 16
(EXPERIENCE DETAILS FOR NEW & RETROFIT WORK)
Experience details for various
Sl. |
Client |
Type of |
Unit Size |
Date of |
Type of |
Input/output |
Type of |
Type of |
Catalyst |
Brief |
Bidder’s |
No. |
Name & |
coal & |
& No. of |
Commissio |
value of Nox |
Job |
Boiler |
supplier |
scope |
Scope of |
|
|
Address |
%age of |
Units |
ning |
technology |
(mg/NM3) |
(New / |
(tower/two |
name |
of |
work |
|
|
Ash |
|
|
|
|
retrofit) |
pass, |
and type |
work |
|
|
|
|
|
|
|
|
|
tangentail/ |
of |
|
|
|
|
|
|
|
|
|
|
wall fired) |
catalyst |
|
|
1. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*This sheet is to be filled separately for each type of
Schedule – 3
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 17
(TURNOVER OF THE COMPANY IN THE LAST THREE FINANCIAL YEARS AND
NETWORTH OF THE COMPANY)
A) We confirm that annual turnover of M/s......................................... [Applicant] for the preceding three financial years is indicated below:-
Sl. No. |
Financial Year |
Turnover |
Turnover |
Exchange Rate as on |
|
|
amount |
amount |
seven (7) days prior to |
|
|
In |
(Rs |
date of bid |
|
|
Bidder's |
Million) |
opening |
|
|
Currency |
|
|
1. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
We have enclosed Balance Sheets and Profit & Loss account duly certified by Chartered Accountant
B) |
We hereby confirm that net worth of M/s |
||
|
the last day of the preceding financial year on the date of Bid opening is |
||
|
given below:- |
|
|
|
|
|
|
Sl. No. |
Description |
As on last day of the |
|
|
|
|
preceding financial year |
1. |
|
|
|
2. |
|
Net worth |
|
3. |
|
%age of Net worth to |
|
Schedule – 4
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 18
(PAST EXPERIENCE WITH REGARD TO INSTALLATION/RETROFITTING
OF VARIOUS
We hereby furnish past experience data for each DeNox technologies i.e. Combustion modification, SNCR & SCR or any other technology (strike off whichever is not applicable)
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 19
(COMBUSTION SYSTEM MODIFICATION)
(Furnish detail of all pulverised coal fired units where modification in Combustion system/Staging of air done by you to reduce NOx emission as a retrofit work)
Detail of plants executed by us where Combustion system/staging of air is modified to reduce NOx emission in a pulverised coal fired power plant which is in successful operation. The details of same are furnished below:
Sl.No. |
Description |
Detail |
|
|
|
1. |
Name of the Client |
|
|
|
|
|
Client name & address |
|
|
Telephone No.: |
|
|
Fax No.: |
|
|
|
|
|
|
|
2. |
Name & Location of Plant |
|
|
|
|
3. |
Offered Technology |
Modification in |
|
|
combustion system / |
|
|
staging of air |
|
|
|
4. |
Unit Capacity (MW) |
|
|
|
|
5. |
Whether Retrofitted/ new |
|
|
|
|
6. |
Type of Boiler |
|
|
Tower type/ two pass |
|
|
Tangential fired/ Wall fired |
|
|
|
|
7. |
Contract No. & Date |
|
|
|
|
|
Starting date of Project |
|
|
Scheduled date of Commissioning |
|
|
Actual date of Commissioning |
|
|
Date of commencement of successful operation |
|
|
|
|
8. |
Scope of work executed by |
|
|
us for the aforesaid modification work includes the |
|
|
following : |
|
|
|
|
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 20
|
a) |
Designed |
Yes*/No* |
|
|
|
|||
|
b) |
Engineered |
Yes*/No* |
|
|
|
|||
|
c) |
*Manufactured/*Got manufactured |
Yes*/No* |
|
|
|
|||
|
d) |
*Erection/*Supervised |
Yes*/No* |
|
|
|
|||
|
|
erection/**Acted as Advisor for |
|
|
|
|
erection |
|
|
|
e) |
*Commissioned/*Supervised |
Yes*/No* |
|
|
|
|||
|
|
commissioning/**Acted as advisor |
|
|
|
|
for commissioning |
|
|
|
f) |
Whether the plant is in successful |
Yes*/No* |
|
|
|
|||
|
|
operation for a period of one (1) year |
|
|
|
|
(minimum) as on date of techno- |
|
|
|
|
commercial bid opening |
|
|
|
|
Note: In case answer is “No” in any of |
|
|
|
|
the above, pl. indicate the name of the |
|
|
|
|
Agency. |
|
|
9. |
Whether Civil, structural work for aforesaid |
|
||
|
modification work has been executed (YES/NO) |
|||
10. |
|
|
Type of coal used |
|
|
|
|
i) Max. HHV (Kcal/Kg) |
|
|
|
|
ii) Min. HHV (Kcal/Kg) |
|
|
|
|
iii) Max. Ash content (%) |
|
|
|
|
iv) Max. total moisture content (%) |
|
|
|
|
v) Volatile matter content (%) |
|
11. |
Name |
of combustion modification technology |
||
|
provider |
|
||
|
|
|||
12. |
Input parameters considered for combustion |
|||
|
system design |
|
||
|
|
a. Nitrogen range in coal |
|
|
|
|
b. |
Coal fired in T/hr |
|
|
|
c. |
No. of Mills |
|
|
|
d. Load range of unit considered for the NOx |
||
|
|
|
guarantee |
|
13.NOx value in mg/Nm³ on dry & 6% oxygen basis prior to the combustion system modification
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 21
14. |
Guaranteed parameter |
|
|
a. NOx output |
|
|
b. Excess air |
|
|
c. Unburnt carbon |
|
|
d. Change in boiler efficiency |
|
|
e. Change in aux power consumption |
|
|
|
|
15. |
Detail of Combustion system modification |
|
|
|
|
|
whether wind box modified if yes detail for same |
|
|
and burner detail |
|
|
|
|
|
whether burner design changed if yes furnish |
|
|
details |
|
|
|
|
|
Whether additional OFA, BOFA,SOFA provided |
|
|
|
|
|
Whether Mill provided with dynamic classifier or |
|
|
not. Further If changed pl. indicate |
|
|
|
|
16. |
Any other requirement |
|
|
|
|
17. |
Pl. indicate any major relocation or change of |
|
|
existing equipment due to retrofitting of SNCR |
|
|
system |
|
|
|
|
18. |
Achieved value of NOx in Mg/Nm3 |
|
|
|
|
19. |
Pl. include layout, scheme and GA drgs of |
|
|
reference project |
|
|
|
|
20. |
Schedule for completion of modification from date |
|
|
of award |
|
|
|
|
21. |
Unit outage/Shutdown time |
|
|
|
|
22. |
Approximate cost of modification |
|
|
|
|
Note:
* Please Strike off whichever is not applicable
This sheet is to be filled separately for each reference plant.
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 22
(SELECTIVE
(Furnish detail of all pulverised coal fired units where SNCR system installed by you)
Detail of plants executed by us as new/ retrofitting of Selective Non Catalytic Reduction (SNCR) system for NOx emission control in a pulverised coal fired power plant which is in successful operation. The details of same are furnished below:
Sl.No. |
Description |
|
Detail |
|
|
|
|
|
|
1. |
Name of the Client |
|
|
|
|
|
|
|
|
|
Client name & address |
|
|
|
|
Telephone No.: |
|
|
|
|
Fax No.: |
|
|
|
|
|
|
||
|
|
|
|
|
2. |
Name & Location of Plant |
|
|
|
|
|
|
|
|
3. |
Offered Technology |
|
SNCR |
|
|
|
|
|
|
4. |
Unit Capacity (MW) |
|
|
|
|
|
|
|
|
5. |
Whether Retrofitted/ new |
|
|
|
|
|
|
|
|
6. |
Type of Boiler |
|
|
|
|
Tower type/ two pass |
|
|
|
|
Tangential fired/ Wall fired |
|
|
|
|
|
|
|
|
7. |
Contract No. & Date |
|
|
|
|
|
|
||
|
Starting date of Project |
|
|
|
|
Scheduled date of Commissioning |
|
|
|
|
Actual date of Commissioning |
|
|
|
|
Date of commencement of successful operation |
|
||
|
|
|
||
8. |
Scope of work executed by us for the aforesaid |
|
||
|
SNCR system includes the following : |
|
|
|
|
a) |
Designed |
Yes*/No* |
|
|
|
|
||
|
b) |
Engineered |
Yes*/No* |
|
|
|
|
||
|
c) |
*Manufactured/*Got manufactured |
Yes*/No* |
|
|
|
|
||
|
|
|
|
|
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 23
|
d) |
*Erection/*Supervised |
Yes*/No* |
|
|
|
|
||
|
|
erection/**Acted as Advisor for |
|
|
|
|
erection |
|
|
|
e) |
*Commissioned/*Supervised |
Yes*/No* |
|
|
|
|
||
|
|
commissioning/**Acted as advisor |
|
|
|
|
for commissioning |
|
|
|
f) |
Whether the plant is in successful |
Yes*/No* |
|
|
|
|
||
|
|
operation for a period of one (1) year |
|
|
|
|
(minimum) as on date of techno- |
|
|
|
|
commercial bid opening |
|
|
|
|
Note: In case answer is “No” in any of |
|
|
|
|
the above, pl. indicate the name of |
|
|
|
|
the Agency. |
|
|
9. |
Whether Civil, structural work for SNCR system has |
|
||
|
been executed (YES/NO) |
|
|
|
|
|
|
|
|
10. |
|
Type of coal used |
|
|
|
|
i) Max. HHV (Kcal/Kg) |
|
|
|
|
ii) Min. HHV (Kcal/Kg) |
|
|
|
|
iii) Max. Ash content (%) |
|
|
|
|
iv) Max. total moisture content (%) |
|
|
|
|
v) Volatile matter content (%) |
|
|
11. |
Name of SNCR technology provider |
|
|
|
|
|
|
||
12. |
Input parameters considered for SNCR design |
|
||
|
|
a. NOx value in mg/Nm³ on dry & 6% oxygen |
|
|
|
|
basis |
|
|
|
|
b. SO3 concentration |
|
|
|
|
c. Flue gas flow rate (Nm3/s) |
|
|
|
|
d. Inlet dust burden in g/Nm3 |
|
|
|
|
e. Temperature input range |
|
|
|
|
f. Load range of unit considered for the NOx |
|
|
|
|
guarantee |
|
|
|
|
|
||
13. |
Output parameters considered for SNCR design |
|
||
|
i) |
NOx value in mg/Nm³ on dry & 6% oxygen |
|
|
|
|
basis |
|
|
|
ii) |
Ammonia slip |
|
|
|
|
|
|
|
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 24
14.Guaranteed parameter
a.NOx output
b.Ammonia Slip
c.SO3 conversion rate
d.Reagent consumption rate
15.Detail of SNCR system
Type of SNCR system
No. of reagent injection levels per boiler and its location
16.Type of Reagent used (Urea or Anhydrous NH3 or Aqueous NH3 etc.)
Reagent consumption rate (kg/hr)
Temperature range for reagent injection (oC) for each location
Type of Control system for reagent injection Space for Reagent storage & handling (m2) Type of injection system
17.Auxiliary Power Consumption for SNCR System (KW)
18.Requirement of water for SNCR system
19.Requirement of Auxiliary steam for SNCR system
20.Requirement of Compressed air
21.Any other requirement
22.Pl. indicate any major relocation or change of existing equipment due to retrofitting of SNCR system
23.Achieved value of NOx in Mg/Nm3
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 25
24. |
Pl. include layout, scheme and GA |
drgs of |
|
|
reference project |
|
|
|
|
|
|
25. |
Feedback on effect of Ammonium bisulphate on |
|
|
|
downstream components like APH |
chocking / |
|
|
blockage etc. |
|
|
|
|
|
|
26. |
Schedule for completion of modification from date |
|
|
|
of award |
|
|
|
|
|
|
27. |
Unit outage/Shutdown time |
|
|
|
|
|
|
28. |
Approximate cost of modification |
|
|
|
|
|
|
Note:
* Please Strike off whichever is not applicable
This sheet is to be filled separately for each reference plant.
(SELECTIVE CATALYTIC REDUCTION (SCR) SYSTEM)
(Furnish detail of all pulverised coal fired units where SCR system retrofitted by
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 26
you)
Detail of plants executed by us as retrofitting of Selective Catalytic Reduction (SCR) system for NOx emission control in a pulverised coal fired power plant which is in successful operation. The details of same are furnished below:
Sl.No. |
Description |
Detail |
|
|
|
1. |
Name of the Client |
|
|
|
|
|
Client name & address |
|
|
Telephone No.: |
|
|
Fax No.: |
|
|
|
|
|
|
|
2. |
Name & Location of Plant |
|
|
|
|
3. |
Offered Technology |
SCR |
|
|
|
4. |
Unit Capacity (MW) |
|
|
|
|
5. |
Whether plant is pulverised coal fired |
Yes |
|
|
|
6. |
Type of Boiler |
|
|
Tower type/ two pass |
|
|
Tangential fired/ Wall fired |
|
7Contract No. & Date Starting date of Project
Scheduled date of Commissioning Actual date of Commissioning
Date of commencement of successful operation
8. |
Scope of work executed by us for the aforesaid SCR |
||
|
system includes the following: |
|
|
|
a) |
Designed |
Yes*/No* |
|
|
||
|
b) |
Engineered |
Yes*/No* |
|
|
||
|
c) |
*Manufactured/*Got manufactured |
Yes*/No* |
|
|
||
|
d) |
*Erection/*Supervised |
Yes*/No* |
|
|
||
|
|
erection/**Acted as Advisor for |
|
|
|
erection |
|
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 27
|
e) |
*Commissioned/*Supervised |
Yes*/No* |
|
|
|
|
||
|
|
commissioning/**Acted as advisor |
|
|
|
|
for commissioning |
|
|
|
f) |
Whether the plant is in successful |
Yes*/No* |
|
|
|
|
||
|
|
operation for a period of one (1) year |
|
|
|
|
(minimum) as on date of techno- |
|
|
|
|
commercial bid opening |
|
|
|
|
Note: In case answer is “No” in any of |
|
|
|
|
the above, pl. indicate the name of |
|
|
|
|
the Agency. |
|
|
9. |
Whether Civil, structural work for SCR system has |
|
||
|
been executed (YES/NO) |
|
|
|
|
|
|
|
|
10. |
|
Type of coal used |
|
|
|
|
i) Max. HHV (Kcal/Kg) |
|
|
|
|
ii) Min. HHV (Kcal/Kg) |
|
|
|
|
iii) Max. Ash content (%) |
|
|
|
|
iv) Max. total moisture content (%) |
|
|
|
|
v) Volatile matter content (%) |
|
|
11. |
Name of catalyst supplier |
|
|
|
|
Type of catalyst ( Plate/Honeycomb/Corrugated/ |
|
||
|
other) |
|
|
|
|
|
|
||
12. |
No. of Air Pre heater and type of air heater i.e. |
|
||
|
bisector/ Trisector |
|
|
|
|
|
|
||
13. |
Input parameters considered for SCR design |
|
||
|
a. NOx value in mg/Nm³ on dry & 6% oxygen |
|
||
|
|
basis |
|
|
|
b. SO3 concentration |
|
|
|
|
c. Flue gas flow rate (Nm3/s) |
|
|
|
|
d. Inlet dust burden in g/Nm3 |
|
|
|
|
e. Temperature input range |
|
|
|
|
f. Load range of unit considered for the NOx |
|
||
|
|
guarantee |
|
|
|
|
|
||
14. |
Output parameters considered for SCR design |
|
||
|
a. NOx value in mg/Nm³ on dry & 6% oxygen |
|
||
|
|
|
|
|
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 28
|
basis |
|
|
b. Noise level |
|
|
c. SO2 to SO3 oxidation rate in SCR |
|
|
d. SO3 concentration in flue gas at SCR outlet |
|
|
e. Conversion of elemental mercury to oxidized |
|
|
mercury (%) (if measured) |
|
|
|
|
15. |
Guaranteed parameter |
|
|
a. NOx output |
|
|
b. Ammonia Slip |
|
|
c. SO3 conversion rate |
|
|
d. Pressure drop across SCR |
|
|
e. Catalyst life |
|
|
|
|
16. |
Detail of SCR system |
|
|
|
|
|
No. of SCR reactors per boiler |
|
|
|
|
|
Each SCR reactor dimension (LXWxH)(m) |
|
|
|
|
|
No. of layers of catalyst |
|
|
|
|
|
Provision of additional catalyst layer addition |
|
|
(Specify no. of layers) |
|
|
|
|
|
Volume of catalyst |
|
|
|
|
|
SCR bypass for catalyst protection provided |
Yes / No |
|
|
|
|
Economiser bypass provided |
Yes / No |
|
|
|
|
Flue gas Velocity through SCR system (m/sec) |
|
|
|
|
|
Weight of SCR system for structure design and |
|
|
hoist capacity |
|
|
Type of catalyst cleaning equipment and its |
|
|
requirements |
|
|
|
|
|
Catalyst erosion protection |
|
|
screen provided above SCR or not |
|
|
|
|
|
Number of sample elements for catalyst |
|
|
surveillance testing |
|
|
|
|
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 29
|
Platform lay down space to accommodate catalyst |
|
loading |
|
|
17. |
Reagent Used- Anhydrous/aqueous Ammonia/ |
|
urea |
|
|
|
Reagent consumption rate (kg/hr) |
|
|
|
Type of Control system for reagent injection |
|
|
|
Space for Reagent storage & handling (m2) |
|
Storage for how many days |
|
|
18. |
Auxiliary Power Consumption for SCR System |
|
(KW) |
|
|
19. |
Requirement of water for SCR system |
|
|
20. |
Requirement of Auxiliary steam for SCR system |
|
|
21. |
Requirement of Compressed air |
|
|
22. |
Any other requirement |
|
|
23. |
Achieved value of NOx in Mg/Nm3 |
|
|
24. |
Pl. indicate any major relocation or change of |
|
existing equipment due to retrofitting of SCR |
|
system |
|
|
25. |
Pl. include layout, scheme and GA drgs of |
|
reference project |
|
|
26. |
Feedback on APH element replacement with new |
|
material to cater effects of Ammonium by sulphate |
|
|
27. |
Schedule for completion of modification from date |
|
of award |
28.Unit outage/Shutdown time
29.Approximate cost of modification
Note:
* Please Strike off whichever is not applicable
This sheet is to be filled separately for each reference plant.
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 30
(SELECTIVE CATALYTIC REDUCTION (SCR) SYSTEM)
(Furnish detail of all pulverised coal fired units where SCR system installed by you in new installation)
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 31
Detail of plants executed by us as retrofitting of Selective Catalytic Reduction (SCR) system for NOx emission control in a pulverised coal fired power plant which is in successful operation. The details of same are furnished below:
Sl.No. |
Description |
|
Detail |
|
|
|
|
|
|
1. |
Name of the Client |
|
|
|
|
|
|
|
|
|
Client name & address |
|
|
|
|
Telephone No.: |
|
|
|
|
Fax No.: |
|
|
|
|
|
|
||
|
|
|
|
|
2. |
Name & Location of Plant |
|
|
|
|
|
|
|
|
3. |
Offered Technology |
|
SCR |
|
|
|
|
|
|
4. |
Unit Capacity (MW) |
|
|
|
|
|
|
|
|
5. |
Whether plant is pulverised coal fired |
|
Yes |
|
|
|
|
|
|
6. |
Type of Boiler |
|
|
|
|
Tower type/ two pass |
|
|
|
|
Tangential fired/ Wall fired |
|
|
|
|
|
|
|
|
7 |
Contract No. & Date |
|
|
|
|
|
|
||
|
Starting date of Project |
|
|
|
|
Scheduled date of Commissioning |
|
|
|
|
Actual date of Commissioning |
|
|
|
|
Date of commencement of successful operation |
|
||
|
|
|
||
8. |
Scope of work executed by us for the aforesaid SCR |
|
||
|
system includes the following: |
|
|
|
|
a) |
Designed |
Yes*/No* |
|
|
|
|
||
|
b) |
Engineered |
Yes*/No* |
|
|
|
|
||
|
c) |
*Manufactured/*Got manufactured |
Yes*/No* |
|
|
|
|
||
|
d) |
*Erection/*Supervised |
Yes*/No* |
|
|
|
|
||
|
|
erection/**Acted as Advisor for |
|
|
|
|
erection |
|
|
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 32
|
e) |
*Commissioned/*Supervised |
Yes*/No* |
|
|
||
|
|
commissioning/**Acted as advisor |
|
|
|
for commissioning |
|
|
f) |
Whether the plant is in successful |
Yes*/No* |
|
|
||
|
|
operation for a period of one (1) year |
|
|
|
(minimum) as on date of techno- |
|
|
|
commercial bid opening |
|
|
|
Note: In case answer is “No” in any of |
|
|
|
the above, pl. indicate the name of |
|
|
|
the Agency. |
|
9. |
Whether Civil, structural work for SCR system has |
||
|
been executed (YES/NO) |
|
|
|
|
|
|
10. |
|
Type of coal used |
|
|
|
i) Max. HHV (Kcal/Kg) |
|
|
|
ii) Min. HHV (Kcal/Kg) |
|
|
|
iii) Max. Ash content (%) |
|
|
|
iv) Max. total moisture content (%) |
|
|
|
v) Volatile matter content (%) |
|
|
|
|
|
11. |
Name of catalyst supplier |
|
|
|
Type of catalyst ( Plate/Honeycomb/Corrugated/ |
||
|
other) |
|
|
|
|
||
12. |
No. of Air Pre heater and type of air heater i.e. |
||
|
bisector/ Trisector |
|
13.Input parameters considered for SCR design
a.NOx value in mg/Nm³ on dry & 6% oxygen basis
b.SO3 concentration
c.Flue gas flow rate (Nm3/s)
d.Inlet dust burden in g/Nm3
e.Temperature input range
f.Load range of unit considered for the NOx guarantee
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 33
14. |
Output parameters considered for SCR design |
|
|
a. NOx value in mg/Nm³ on dry & 6% oxygen |
|
|
basis |
|
|
b. Noise level |
|
|
c. SO2 to SO3 oxidation rate in SCR |
|
|
d. SO3 concentration in flue gas at SCR outlet |
|
|
e. Conversion of elemental mercury to oxidized |
|
|
mercury (%) (if measured) |
|
|
|
|
15. |
Guaranteed parameter |
|
|
a. NOx output |
|
|
b. Ammonia Slip |
|
|
c. SO3 conversion rate |
|
|
d. Pressure drop across SCR |
|
|
e. Catalyst life |
|
|
|
|
16. |
Detail of SCR system |
|
|
|
|
|
No. of SCR reactors per boiler |
|
|
|
|
|
Each SCR reactor dimension (LXWxH)(m) |
|
|
|
|
|
No. of layers of catalyst |
|
|
|
|
|
Provision of additional catalyst layer addition |
|
|
(Specify no. of layers) |
|
|
|
|
|
Volume of catalyst |
|
|
|
|
|
SCR bypass for catalyst protection provided |
Yes / No |
|
|
|
|
Economiser bypass provided |
Yes / No |
|
|
|
|
Flue gas Velocity through SCR system (m/sec) |
|
|
|
|
|
Weight of SCR system for structure design and |
|
|
hoist capacity |
|
|
Type of catalyst cleaning equipment and its |
|
|
requirements |
|
|
|
|
|
Catalyst erosion protection |
|
|
screen provided above SCR or not |
|
|
|
|
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 34
|
Number of sample elements for catalyst |
|
surveillance testing |
|
|
|
Platform lay down space to accommodate catalyst |
|
loading |
|
|
17. |
Reagent Used- Anhydrous/aqueous Ammonia/ |
|
urea |
|
|
|
Reagent consumption rate (kg/hr) |
|
|
|
Type of Control system for reagent injection |
|
|
|
Space for Reagent storage & handling (m2) |
|
Storage for how many days |
|
|
18. |
Auxiliary Power Consumption for SCR System |
|
(KW) |
|
|
19. |
Requirement of water for SCR system |
|
|
20. |
Requirement of Auxiliary steam for SCR system |
|
|
21. |
Requirement of Compressed air |
|
|
22. |
Any other requirement |
|
|
23. |
Achieved value of NOx in Mg/Nm3 |
|
|
24. |
Pl. indicate any major relocation or change of |
|
existing equipment due to retrofitting of SCR |
|
system |
|
|
25. |
Pl. include layout, scheme and GA drgs of |
|
reference project |
|
|
26. |
Feedback on APH element replacement with new |
|
material to cater effects of Ammonium by sulphate |
|
|
27. |
Schedule for completion of modification from date |
|
of award |
|
|
28. |
Unit outage/Shutdown time |
29.Approximate cost of modification
Note:
* Please Strike off whichever is not applicable
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 35
This sheet is to be filled separately for each reference plant.
(SELECTIVE CATALYTIC REDUCTION (SCR) SYSTEM)
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 36
(Furnish detail of all pulverised coal fired units where other technological intervenes/arrangements installed by you)
Detail of plants where other technological intervenes/arrangements executed by us as new/ retrofit work for NOx emission control in a pulverised coal fired power plant which is in successful operation. The details of same are furnished below:
Sl.No. |
Description |
Detail |
|
|
|
1. |
Name of the Client |
|
|
|
|
|
Client name & address |
|
|
Telephone No.: |
|
|
Fax No.: |
|
|
|
|
|
|
|
2. |
Name & Location of Plant |
|
|
|
|
3. |
Offered Technology |
|
|
|
|
4. |
Unit Capacity (MW) |
|
|
|
|
5. |
Type of Boiler |
|
|
Tower type/ two pass |
|
|
Tangential fired/ Wall fired |
|
6Contract No. & Date Starting date of Project
Scheduled date of Commissioning Actual date of Commissioning
Date of commencement of successful operation
7.Scope of work executed by us for the aforesaid technology includes the following:
a) |
Designed |
Yes*/No* |
|
||
b) |
Engineered |
Yes*/No* |
|
||
c) |
*Manufactured/*Got manufactured |
Yes*/No* |
|
||
d) |
*Erection/*Supervised |
Yes*/No* |
|
||
|
erection/**Acted as Advisor for |
|
|
erection |
|
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 37
e)
*Commissioned/*Supervised Yes*/No* commissioning/**Acted as advisor
for commissioning
f)
Whether the plant is in successful Yes*/No* operation for a period of one (1) year
(minimum) as on date of techno- commercial bid opening
Note: In case answer is “No” in any of the above, pl. indicate the name of the Agency.
8.Whether Civil, structural work for aforesaid technology has been executed (YES/NO)
9. |
Type of coal used |
i)Max. HHV (Kcal/Kg)
ii)Min. HHV (Kcal/Kg)
iii)Max. Ash content (%)
iv)Max. total moisture content (%)
v)Volatile matter content (%)
10.Input parameters considered for design
a.NOx value in mg/Nm³ on dry & 6% oxygen basis
b.SO3 concentration
c.Flue gas flow rate (Nm3/s)
d.Inlet dust burden in g/Nm3
e.Temperature input range
f.Load range of unit considered for the Nox guarantee
11.Output parameters considered for design
a.Nox value in mg/Nm³ on dry & 6% oxygen basis
b.Noise level
c.SO2 to SO3 oxidation rate
d.SO3 concentration in flue gas before and after
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 38
|
|
modification work |
|
|
e. Conversion of elemental mercury to oxidized |
|
|
|
|
mercury (%) (if measured) |
|
|
|
|
|
12. |
Guaranteed parameter |
|
|
|
a. |
Nox output |
|
|
b. |
SO3 conversion rate |
|
|
c. |
Increase in flue gas pressure drop due to |
|
|
|
modification |
|
|
|
|
|
13. |
Any reagent/chemical used |
|
|
|
|
|
|
|
Reagent consumption rate (kg/hr) |
|
|
|
|
|
|
|
Type of Control system for reagent injection |
|
|
|
|
|
|
|
Space for Reagent storage & handling (m2) |
|
|
|
Storage for how many days |
|
|
|
|
|
|
14. |
Increase in Auxiliary Power Consumption due to |
|
|
|
modification (KW) |
|
|
|
|
|
|
15. |
Requirement of water |
|
|
|
|
|
|
16. |
Requirement of Auxiliary steam |
|
|
|
|
|
|
17. |
Requirement of Compressed air |
|
|
|
|
|
|
18. |
NOx value before and after retrofit work (mg/Nm3) |
|
|
|
|
|
|
19. |
Any other requirement |
|
|
|
|
|
|
20. |
Pl. indicate any major relocation or change of |
|
|
|
existing equipment required for modification |
|
|
|
|
|
|
21. |
Pl. include layout, scheme and GA drgs of |
|
|
|
reference project |
|
|
|
|
|
|
22. |
Schedule for completion of modification from date |
|
|
|
of award |
|
|
|
|
|
|
23. |
Unit outage/Shutdown time |
|
|
|
|
|
|
24. |
Approximate cost of modification |
|
|
|
|
|
|
Note:
* Please Strike off whichever is not applicable
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 39
This sheet is to be filled separately for each reference plant.
Schedule – 5
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 40
We hereby furnish the detail of past
Schedule – 6
(PROPOSAL FOR INSTALLATION OF DEMO/ SLIP STREAM PLANT)
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 41
We are willing to install a small pilot level SCR demonstration plant by taking slip stream (around 1500 Nm3/hr) at our own expense. Information collected from this pilot plant would be useful for selection and designing of SCR System suitable for Indian coal(s).This test will be performed along with involvement of NTPC and we will share the outcomes of the test along with all data collected during the test with NTPC. Detail of this proposal is attached herewith. We request that consumable (i.e. Power, water, auxiliary steam, compressed air and Ammonia etc) required during study shall be provided by NTPC. Required quantity of same is indicated in our proposal. In case a coal fired unit is offered to us for the pilot test, we will discuss and finalise detailed test protocol with NTPC within 2 week’s time.
Proposal shall cover the following:-
1.Purpose
2.Scope of work
3.Test facility details with diagram
4.Test method
5.Erection Schedule
6.Test schedule
7.Test conditions
8.Shut down time required
9.Utility required from Employer
10.Measurement
11.Collected data to be shared
12.Result
*In case applicant do not manufacturer their own catalyst then demo plant of their associate/
Schedule – 7
(FORM FOR ACCEPTANCE OF FRAUD PREVENTION POLICY)
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 42
We have read the contents of Fraud Prevention Policy of NTPC displayed on its tender website http://www.ntpctender.com and undertake that we shall strictly abide by the provisions of Fraud Prevention Policy of NTPC.
Schedule – 8
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 43
(ANY OTHER INFORMATION)
Additional Information relevant to the work / assignment is enclosed.
EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM
FOR VARIOUS NTPC PLANTS 44