NTPC Limited

(A Government of India Enterprise)

EXPRESSION OF INTEREST (EOI)

FOR

RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR

VARIOUS NTPC PLANTS

DOCUMENT NO.: CS-0000-407A-9

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 1

SECTION-I: INVITATION FOR EXPRESSION OF INTEREST

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 2

(ABRIDGED INVITATION FOR EXPRESSION OF INTEREST)

NTPC LIMITED

(A Govt. of India Enterprise)

CORPORATE CONTRACTS, NOIDA

INVITATION FOR EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOx EMISSION CONTROL SYSTEM FOR VARIOUS NTPC PLANTS

EOI No.: CS-0000-407A-9

Date: 24/02/2016

NTPC invites EOI from reputed agencies (Boiler manufacturer and SCR / NOx emission control technology suppliers) in India and abroad.

EOI shall be received upto 1500 hrs (IST) on 25.03.2016.

For detailed EOI and documents, please visit at www.ntpctender.com or www.ntpc.co.in or may contact Manager (CS-P&S) / DGM (CS-P&S), NTPC limited, 6th Floor, Engineering Office Complex, A-8A, Sector-24, Noida-201301, Distt. Gautam Budh Nagar (U.P.), India.

Tel. No.: 0091-120-4946619 / 4946642

Fax No.: 0091-120-2410011

e-mail: itisur@ntpc.co.in/ksudhakar@ntpc.co.in

Registered office: NTPC Bhawan, SCOPE Complex, 7, Institutional Area, Lodi Road, New Delhi-110003. CIN: L40101DL1975GOI007966, Website: www.ntpc.co.in

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 3

(DETAILED INVITATION FOR EXPRESSION OF INTEREST)

INVITATION FOR EXPRESSION OF INTEREST (EOI)

FOR

RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR

VARIOUS NTPC PLANTS

EOI No.: CS-0000-407A-9

Date: 24/02/2016

1.0INTRODUCTION

NTPC invites Expression of Interest from reputed agencies (Boiler manufacturer and SCR / NOx emission control technology suppliers) in India and abroad who have experience in NOx emission control technology (i.e. SCR, SNCR, Low NOx firing/combustion system modification or any of its combination) and need it for retrofit in its various coal based thermal units.

2.0SCOPE OF WORK

The brief scope of work for Retrofitting of NOx Emission Control System for various NTPC plants would basically involve retrofitting of feasible technology like SCR, SNCR, Low NOx firing/combustion system modification or any of its combination for its various units to control the NOx emission as per the notification dated 8th December 2015 by Ministry of Environment, Forest and Climate Change.

3.0INTENT OF THE EXPRESSION OF INTEREST (EOI)

Through this EOI, NTPC intends to seek the willingness of reputed agencies to participate in various NOx control initiatives which NTPC intends to take in near future by suitably retrofitting its existing coal fired units and to collect past data from these agencies in respect of experience, financial, capability for NOx reduction with various technology, techno-economics of various technologies who have experience in Retrofitting/ supplying of NOx Emission Control System (i.e. SCR, SNCR, Combustion system modification or any of its combination).

4.0ELIGIBILITY

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 4

Agencies of repute who meet any of the following criteria are invited to submit their application for Expression of Interest (EOI):

(i)Manufacturer of Steam Generator of units of capacity of 200MW or above

(ii)Agencies who have supplied/executed contract for retrofitting jobs of NOx emission control operating at any one single power plant successfully for one years.

(iii)Indian agencies who have tie ups with foreign agencies who have the capabilities as at (i) or (ii) above.

(iv)Indian subsidiaries/ Indian Joint ventures/ Indian promoters of JV companies of foreign agencies who jointly meet the capabilities as at (i) or (ii) above.

5.0DOWNLOAD AND SUBMISSION OF EOI

Interested agencies may download the documents of EOI free of cost from www.ntpctender.com. The agencies shall submit their duly filled EOI through e- mail to itisur@ntpc.co.in on or before 25.03.2016 (1500 hrs (IST)).

6.0NTPC reserves the right to reject or accept any or all applications, cancel/withdraw the EOI process without assigning any reason whatsoever and in such case no applicant / intending applicant shall have any claim arising out of such action.

7.0Address for Communication

Manager (Contract Services-P&S)/ DGM (Contract Services-P&S), NTPC Limited, Sixth Floor, Engineering Office Complex,

A-8A, Sector-24, NOIDA,

Distt. Gautam Budh Nagar, (UP), INDIA, Pin - 201301 Fax No.: 0091-120-2410011

Tel. No.: 0091-120-4946619 / 4946642

e-mail: itisur@ntpc.co.in, ksudhakar@ntpc.co.in

Websites: www.ntpctender.com or www.ntpc.co.in

CIN: L40101DL1975GOI007966

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 5

SECTION-II: INSTRUCTIONS TO APPLICANTS

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 6

INSTRUCTIONS TO APPLICANTS

1.0INTRODUCTION

NTPC was incorporated in the year 1975, with the objective of planning, promoting and organizing an integrated development of Power Stations in India. With an installed capacity of above 45000 MW, NTPC is the largest power generating major in the country. NTPC designated as one of the Maharatna Public Sector Undertaking is poised to become a global giant and the mega power utility has ambitious plan to become 1,28,000 MW plus company by 2032. To realize its goal of becoming 1,28,000 MW Company by 2032, NTPC already has a long list of projects in pipeline.

Sixty-seven (67) numbers of various unit size (mostly 200 & 500 MW size) coal based thermal units installed before 31st Dec, 2003 with cumulative capacity of18185 MW, are operational without having any DeNOx system. This emission value has to be brought down to 600 mg/Nm3.

Coal fired units under operation, installed after 31st Dec, 2003, are 31 in nos having different unit sizes (mostly 500 & 660 MW size). These have cumulative generation capacity of 15590 MW. For these NOx emission level is to brought down to 300 mg/Nm3.

Further, thirty -seven (37) numbers of coal fired units of cumulative capacity 22185 MW are under construction with advanced combustion system in order to reduce the NOx. These units are guaranteed for NOx emission of 260 g/GJ of heat input. These plants are expected to be commissioned within 1-2 years time. This emission value has to be brought down to 100 or 300 mg/Nm3 based on the date of installation.

NTPC invites Expression of Interest from reputed agencies (Boiler manufacturer and SCR / NOx emission control technology suppliers) in India and abroad who have experience in NOx emission control technology (i.e. SCR, SNCR, Low NOx firing/combustion system modification or any of its combination) and need it for retrofit in its various coal based thermal units. Accordingly, ‘Retrofitting of NOx Emission Control System Package’ is

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 7

likely to be floated for installation of DeNOx system to meet the requirements as per new environment norms.

2.0SCOPE OF WORK:

The brief scope of work for Retrofitting of NOx Emission Control System for various NTPC plants would basically involve retrofitting of feasible technology like SCR, SNCR, Low NOx firing/combustion system modification or any of its combination for its various units to control the NOx emission as per the notification dated 8th December 2015 by Ministry of Environment, Forest and Climate Change. This retrofit work will need to be performed with in available space, infrastructure and other constraints in a professional manner.

Details of such NTPC, it’s JV/Subsidiaries owned coal fired units are as under:

NTPC owned operational Coal fired units installed before 31st Dec, 2003

Unit Capacity

Units having capacity

Units having capacity of

(MW)

smaller than 220MW

500MW and above

No. of units

47

20

Total Capacity

8185

10000

(MW)

 

 

NTPC owned operational Coal fired units installed after 31st Dec, 2003

Unit Capacity

Units having capacity

Units having capacity of

(MW)

smaller than 500MW

500MW and above

No. of units

3

28

Total Capacity

1190

14800

(MW)

 

 

NTPC/NTPC’s JV/ Subsidiaries owned, under construction Coal fired units

Unit Capacity

Units having capacity

Units having capacity of

(MW)

smaller than 500MW

500MW and above

No. of units

8

29

Total Capacity

1945

20240

(MW)

 

 

3.0INTENT OF THE EXPRESSION OF INTEREST (EOI)

Through this EOI, NTPC intends to seek the willingness of reputed agencies/boiler manufacturers etc who are willing to participate in various NOx control initiatives which NTPC intends to take in near future by suitably retrofitting its existing coal fired units and to collect past data from these vendors/manufacturers in respect of experience, financial, capability for NOx reduction with various technology, techno-economics of various technologies who have experience in Retrofitting/ supplying of NOx Emission Control System (i.e. SCR, SNCR, Combustion system modification or any of its combination).

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 8

‘Retrofitting of NOx Emission Control System Package’ is likely to be floated for installation of DeNOx system in various operational and under construction coal based units of NTPC, to meet the requirements as per new environment norms, as mentioned at 2.0 above or for the new power stations that NTPC may set-up in future.

This invitation for Expression of Interest is not intended for empanelment or pre- qualification of bidders. Separate NIT shall be floated by NTPC for Retrofitting of NOx Emission Control System Package for existing units and any of its forthcoming projects as and when required.

Further, NTPC reserves the right to include/ exclude any equipment/ system/ facility in the Scope of proposed Retrofitting of NOx Emission Control System for various NTPC plants.

4.0ELIGIBILITY

Agencies of repute who meet any of the following criteria are invited to submit their application for Expression of Interest (EOI):

(v)Manufacturer of Steam generator of units of capacity of 200MW or above

(vi)Agencies who have supplied/executed contract for retrofitting/ new jobs of NOx emission control system i.e. Combustion modification, SNCR or SCR system in past for pulverised coal based thermal power units of capacity 200MW or above and operating at any one single power plant successfully for one years.

(vii)Indian agencies who have tie ups with foreign Contractors who have the capabilities as at (i) or (ii) above.

(viii)Indian subsidiaries/ Indian Joint ventures/ Indian promoters of JV companies of foreign agencies who jointly meet the capabilities as at (i) or (ii) above.

5.0DOCUMENTS OF EOI

The EOI documents shall comprise of the following sections:

(i)Section-I: Invitation for Expression of Interest

(ii)Section-II: Instructions to Applicants

(ii) Section-III: Form of Application & Schedules

6.0Documents comprising the Application

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 9

The application of EOI shall comprise the following:

A)Form of Application: The form of application shall indicate willingness of agencies to participate in the appropriate De-Nox retrofit, as and when NTPC invite proposal for same.

B)Schedules:

a.Schedule-1:Company profile and Organization Structure

b.Schedule-2: Experience details of the Company for the various DeNOx technologies for new plants and retrofitted plants.

c.Schedule-3: Turnover of the company in last three financial years and net worth of the Company.

d.Schedule-4: Past experience with regard to installation/retrofitting the following DeNOx system

(i)Retrofitting the combustion system/staging of air etc.

(ii)Installation of SNCR system

(iii)Retrofitting the operating units by installing SCR system

(iv)Installing SCR system in new installations

(v)Any other technological intervenes /arrangements

e.Schedule-5:- Details of past techno-economic considering the selection of a particular technology - Applicant is required to share details of past techno-economics studies, costs (Capex and Opex), time schedule, planned outage for each of DeNOx retrofit. Desired and achieved NOx emission level, alongwith its advantage and disadvantages. Techno-economics for usage of reagent injection i.e. Anhydrous/aqueous ammonia and urea, if applicable.

f.Schedule-6:- Willingness to participate in installation of a small pilot level SCR demonstration plant by taking slip stream (around 1500 Nm3/hr) at their own cost in one of NTPC operating unit. For such test/study NTPC would bear the cost of consumables like ammonia, power, steam, compressed air etc. In case applicant do not manufacture their own catalyst then demo plant of their associate/sub-vendor of catalyst supplier may be proposed.

g.Schedule-7: Acceptance of Fraud Prevention Policy of NTPC

h.Schedule-8: Any other information

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 10

7.0Submission of Application of EOI

The application of EOI shall be submitted in the following manner:

(i)The Form of Application shall be submitted on the letter head of the company.

(ii)The Schedules shall be submitted in MS word format in one single file.

(ii)The credentials/supporting documents shall be submitted in pdf file

format. (The applicants are advised to combine all credentials/supporting documents in single pdf file.)

The above mentioned documents shall be submitted through e-mail to itisur@ntpc.co.in. No manual or hard copy submission shall be accepted.

8.0Deadline for submission of Application of EOI

The application of EOI must be submitted through e-mail on or before 25.03.2016 (1500 hrs (IST)).

9.0Open House Discussion

NTPC at its discretion may conduct the open house discussion with the agencies who have submitted their EOI. The date and venue of conducting open house discussion shall be intimated later.

10.0EOI process will be subject to verification of all information submitted at the discretion of NTPC. NTPC reserves the right to reject or accept any or all applications, cancel/withdraw the EOI process without assigning any reason whatsoever and in such case no applicant / intending applicant shall have any claim arising out of such action.

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 11

SECTION-III: FORM OF APPLICATION & SCHEDULES

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 12

FORM OF APPLICATION

(To be submitted on Company’s Letter Head)

Ref No.

Date:

Manager (CS-P&S)

NTPC Limited,6th Floor, Engineering Office Complex,

A-8A, Sector – 24, Noida,

Distt. Gautam Budh Nagar

Uttar Pradesh, INDIA 201301

Dear Sir,

Sub: Expression of Interest (EOI) for “Retrofitting of NOx Emission Control System for various NTPC plants”.

We, the undersigned, express our interest for the subject EOI and declare the following:

(a)We are duly authorized to represent and act on behalf of _____________

(name of the firm).

(b)We have examined and have no reservations to the EOI document including Amendment No(s) & Clarification No(s)_________ (if any).

(c)With reference to your invitation for EOI dated _________, we are furnishing herewith all the required details as per the prescribed Schedules.

(d)We hereby express our willingness to participate in appropriate DeNox as and when NTPC invite the proposal for the same.

(e)NTPC and /or its authorized representatives are hereby authorized to conduct any inquiries or investigations to verify the statements, documents and information submitted in connection with this application, and to seek clarifications from our bankers and clients. This application will also serve as authorized on for any individual or authorized representative of any institution referred to in the supporting information, to provide such information deemed necessary and as requested by NTPC.

(f)NTPC and /or its authorized representatives may contact the following nodal persons for further information on any aspects of the application:

Name and designation of

Address for

Telephone

Email

contact Person

Communication

No

ID

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 13

(g)This application is made in the full understanding that:

1.Through this EOI, NTPC intends to only identify the probable vendors in India & abroad who have experience in supplying Nox control emission system i.e. Modification in combustion system, SCR & SNCR and also retrofitted the same in pulverised coal fired units and that this invitation for Expression of Interest is not intended for empanelment or pre- qualification of bidders. Further, intend to install SCR catalyst demo plant in order to get assessment of their catalyst for high ash Indian coal,

2.EOI process will be subject to verification of all information submitted at the discretion of NTPC.

3.NTPC reserves the right to reject or accept any or all applications, cancel the EOI process without any obligation to inform the applicant about the grounds of same.

(h)We declare that we have read and abide by the provisions of Fraud Prevention Policy of NTPC and submit the form of Acceptance of Fraud Prevention Policy duly filled as per NTPC’s format.

(i)The undersigned declare that the statements made and the information provided in the duly completed application are complete, true and correct in every detail.

Name :

In the Capacity of:

Signed

Duly authorized to sign the application for and on behalf of:

Date:

Place:

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 14

SCHEDULES

(SCHEDULES ARE TO BE FILLED UP AND SUBMITTED IN MS WORD FORMAT. All CREDENTIALS/SUPPORTING DOCUMENTS RELEVANT TO THE SCHEDULES ARE TO BE SUBMITTED PREFERABLY IN SINGLE PDF FILE. )

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 15

Schedule – 1

(Company Profile and Organization Structure)

Name of the Company:

Registered Address:

Contact Person & Designation:

Postal address for communication:

Telephone No.:

Fax No.:

E-mail address:

Document regarding Organization Structure and Ownership are enclosed.

Schedule – 2

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 16

(EXPERIENCE DETAILS FOR NEW & RETROFIT WORK)

Experience details for various DE-NOx technologies for new units and retrofitted units

Sl.

Client

Type of

Unit Size

Date of

Type of

Input/output

Type of

Type of

Catalyst

Brief

Bidder’s

No.

Name &

coal &

& No. of

Commissio

De-Nox

value of Nox

Job

Boiler

supplier

scope

Scope of

 

Address

%age of

Units

ning

technology

(mg/NM3)

(New /

(tower/two

name

of

work

 

 

Ash

 

 

 

 

retrofit)

pass,

and type

work

 

 

 

 

 

 

 

 

 

tangentail/

of

 

 

 

 

 

 

 

 

 

 

wall fired)

catalyst

 

 

1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*This sheet is to be filled separately for each type of De-Nox system i.e. SCR, SNCR, Combustion modification etc for New and retrofitted reference plants.

Schedule – 3

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 17

(TURNOVER OF THE COMPANY IN THE LAST THREE FINANCIAL YEARS AND

NETWORTH OF THE COMPANY)

A) We confirm that annual turnover of M/s......................................... [Applicant] for the preceding three financial years is indicated below:-

Sl. No.

Financial Year

Turnover

Turnover

Exchange Rate as on

 

 

amount

amount

seven (7) days prior to

 

 

In

(Rs

date of bid

 

 

Bidder's

Million)

opening

 

 

Currency

 

 

1.

2012-2013

 

 

 

 

 

 

 

 

 

 

 

 

2.

2013-2014

 

 

 

 

 

 

 

 

 

 

 

 

3.

2014-2015

 

 

 

 

 

 

 

 

 

 

 

 

We have enclosed Balance Sheets and Profit & Loss account duly certified by Chartered Accountant

B)

We hereby confirm that net worth of M/s ---------------------- (Applicant) as on

 

the last day of the preceding financial year on the date of Bid opening is

 

given below:-

 

 

 

 

Sl. No.

Description

As on last day of the

 

 

 

preceding financial year

1.

 

Paid-up Share Capital

 

2.

 

Net worth

 

3.

 

%age of Net worth to paid-up Share Capital

 

Schedule – 4

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 18

(PAST EXPERIENCE WITH REGARD TO INSTALLATION/RETROFITTING

OF VARIOUS DE-NOX SYSTEM)

We hereby furnish past experience data for each DeNox technologies i.e. Combustion modification, SNCR & SCR or any other technology (strike off whichever is not applicable) --- carried by us. We are enclosing all relevant details (Technical details atleast cover the points indicated in Schedule-4(i),4(ii) , 4(iii), 4 (iv) & 4 (v) alongwith its tentative layout requirements.

SCHEDULE-4(i)

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 19

(COMBUSTION SYSTEM MODIFICATION)

(Furnish detail of all pulverised coal fired units where modification in Combustion system/Staging of air done by you to reduce NOx emission as a retrofit work)

Detail of plants executed by us where Combustion system/staging of air is modified to reduce NOx emission in a pulverised coal fired power plant which is in successful operation. The details of same are furnished below:

Sl.No.

Description

Detail

 

 

 

1.

Name of the Client

 

 

 

 

 

Client name & address

 

 

Telephone No.:

 

 

Fax No.:

 

 

E-mail address:

 

 

 

 

2.

Name & Location of Plant

 

 

 

 

3.

Offered Technology

Modification in

 

 

combustion system /

 

 

staging of air

 

 

 

4.

Unit Capacity (MW)

 

 

 

 

5.

Whether Retrofitted/ new

 

 

 

 

6.

Type of Boiler

 

 

Tower type/ two pass

 

 

Tangential fired/ Wall fired

 

 

 

 

7.

Contract No. & Date

 

 

 

 

Starting date of Project

 

 

Scheduled date of Commissioning

 

 

Actual date of Commissioning

 

 

Date of commencement of successful operation

 

 

 

 

8.

Scope of work executed by

 

 

us for the aforesaid modification work includes the

 

 

following :

 

 

 

 

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 20

 

a)

Designed

Yes*/No*

 

 

 

b)

Engineered

Yes*/No*

 

 

 

c)

*Manufactured/*Got manufactured

Yes*/No*

 

 

 

d)

*Erection/*Supervised

Yes*/No*

 

 

 

 

erection/**Acted as Advisor for

 

 

 

erection

 

 

e)

*Commissioned/*Supervised

Yes*/No*

 

 

 

 

commissioning/**Acted as advisor

 

 

 

for commissioning

 

 

f)

Whether the plant is in successful

Yes*/No*

 

 

 

 

operation for a period of one (1) year

 

 

 

(minimum) as on date of techno-

 

 

 

commercial bid opening

 

 

 

Note: In case answer is “No” in any of

 

 

 

the above, pl. indicate the name of the

 

 

 

Agency.

 

9.

Whether Civil, structural work for aforesaid

 

 

modification work has been executed (YES/NO)

10.

 

 

Type of coal used

 

 

 

 

i) Max. HHV (Kcal/Kg)

 

 

 

 

ii) Min. HHV (Kcal/Kg)

 

 

 

 

iii) Max. Ash content (%)

 

 

 

 

iv) Max. total moisture content (%)

 

 

 

 

v) Volatile matter content (%)

 

11.

Name

of combustion modification technology

 

provider

 

 

 

12.

Input parameters considered for combustion

 

system design

 

 

 

a. Nitrogen range in coal

 

 

 

b.

Coal fired in T/hr

 

 

 

c.

No. of Mills

 

 

 

d. Load range of unit considered for the NOx

 

 

 

guarantee

 

13.NOx value in mg/Nm³ on dry & 6% oxygen basis prior to the combustion system modification

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 21

14.

Guaranteed parameter

 

 

a. NOx output

 

 

b. Excess air

 

 

c. Unburnt carbon

 

 

d. Change in boiler efficiency

 

 

e. Change in aux power consumption

 

 

 

 

15.

Detail of Combustion system modification

 

 

 

 

 

whether wind box modified if yes detail for same

 

 

and burner detail

 

 

 

 

 

whether burner design changed if yes furnish

 

 

details

 

 

 

 

 

Whether additional OFA, BOFA,SOFA provided

 

 

 

 

 

Whether Mill provided with dynamic classifier or

 

 

not. Further If changed pl. indicate

 

 

 

 

16.

Any other requirement

 

 

 

 

17.

Pl. indicate any major relocation or change of

 

 

existing equipment due to retrofitting of SNCR

 

 

system

 

 

 

 

18.

Achieved value of NOx in Mg/Nm3

 

 

 

 

19.

Pl. include layout, scheme and GA drgs of

 

 

reference project

 

 

 

 

20.

Schedule for completion of modification from date

 

 

of award

 

 

 

 

21.

Unit outage/Shutdown time

 

 

 

 

22.

Approximate cost of modification

 

 

 

 

Note:

* Please Strike off whichever is not applicable

This sheet is to be filled separately for each reference plant.

SCHEDULE-4(ii)

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 22

(SELECTIVE NON-CATALYTIC REDUCTION (SNCR) SYSTEM)

(Furnish detail of all pulverised coal fired units where SNCR system installed by you)

Detail of plants executed by us as new/ retrofitting of Selective Non Catalytic Reduction (SNCR) system for NOx emission control in a pulverised coal fired power plant which is in successful operation. The details of same are furnished below:

Sl.No.

Description

 

Detail

 

 

 

 

1.

Name of the Client

 

 

 

 

 

 

 

Client name & address

 

 

 

Telephone No.:

 

 

 

Fax No.:

 

 

 

E-mail address:

 

 

 

 

 

 

2.

Name & Location of Plant

 

 

 

 

 

 

3.

Offered Technology

 

SNCR

 

 

 

 

4.

Unit Capacity (MW)

 

 

 

 

 

 

5.

Whether Retrofitted/ new

 

 

 

 

 

 

6.

Type of Boiler

 

 

 

Tower type/ two pass

 

 

 

Tangential fired/ Wall fired

 

 

 

 

 

 

 

7.

Contract No. & Date

 

 

 

 

 

 

Starting date of Project

 

 

 

Scheduled date of Commissioning

 

 

 

Actual date of Commissioning

 

 

 

Date of commencement of successful operation

 

 

 

 

8.

Scope of work executed by us for the aforesaid

 

 

SNCR system includes the following :

 

 

 

a)

Designed

Yes*/No*

 

 

 

 

 

b)

Engineered

Yes*/No*

 

 

 

 

 

c)

*Manufactured/*Got manufactured

Yes*/No*

 

 

 

 

 

 

 

 

 

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 23

 

d)

*Erection/*Supervised

Yes*/No*

 

 

 

 

 

 

erection/**Acted as Advisor for

 

 

 

 

erection

 

 

 

e)

*Commissioned/*Supervised

Yes*/No*

 

 

 

 

 

 

commissioning/**Acted as advisor

 

 

 

 

for commissioning

 

 

 

f)

Whether the plant is in successful

Yes*/No*

 

 

 

 

 

 

operation for a period of one (1) year

 

 

 

 

(minimum) as on date of techno-

 

 

 

 

commercial bid opening

 

 

 

 

Note: In case answer is “No” in any of

 

 

 

 

the above, pl. indicate the name of

 

 

 

 

the Agency.

 

 

9.

Whether Civil, structural work for SNCR system has

 

 

been executed (YES/NO)

 

 

 

 

 

 

 

10.

 

Type of coal used

 

 

 

 

i) Max. HHV (Kcal/Kg)

 

 

 

 

ii) Min. HHV (Kcal/Kg)

 

 

 

 

iii) Max. Ash content (%)

 

 

 

 

iv) Max. total moisture content (%)

 

 

 

 

v) Volatile matter content (%)

 

 

11.

Name of SNCR technology provider

 

 

 

 

 

12.

Input parameters considered for SNCR design

 

 

 

a. NOx value in mg/Nm³ on dry & 6% oxygen

 

 

 

basis

 

 

 

 

b. SO3 concentration

 

 

 

 

c. Flue gas flow rate (Nm3/s)

 

 

 

 

d. Inlet dust burden in g/Nm3

 

 

 

 

e. Temperature input range

 

 

 

 

f. Load range of unit considered for the NOx

 

 

 

guarantee

 

 

 

 

 

13.

Output parameters considered for SNCR design

 

 

i)

NOx value in mg/Nm³ on dry & 6% oxygen

 

 

 

basis

 

 

 

ii)

Ammonia slip

 

 

 

 

 

 

 

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 24

14.Guaranteed parameter

a.NOx output

b.Ammonia Slip

c.SO3 conversion rate

d.Reagent consumption rate

15.Detail of SNCR system

Type of SNCR system

No. of reagent injection levels per boiler and its location

16.Type of Reagent used (Urea or Anhydrous NH3 or Aqueous NH3 etc.)

Reagent consumption rate (kg/hr)

Temperature range for reagent injection (oC) for each location

Type of Control system for reagent injection Space for Reagent storage & handling (m2) Type of injection system

17.Auxiliary Power Consumption for SNCR System (KW)

18.Requirement of water for SNCR system

19.Requirement of Auxiliary steam for SNCR system

20.Requirement of Compressed air

21.Any other requirement

22.Pl. indicate any major relocation or change of existing equipment due to retrofitting of SNCR system

23.Achieved value of NOx in Mg/Nm3

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 25

24.

Pl. include layout, scheme and GA

drgs of

 

 

reference project

 

 

 

 

 

25.

Feedback on effect of Ammonium bisulphate on

 

 

downstream components like APH

chocking /

 

 

blockage etc.

 

 

 

 

 

26.

Schedule for completion of modification from date

 

 

of award

 

 

 

 

 

 

27.

Unit outage/Shutdown time

 

 

 

 

 

 

28.

Approximate cost of modification

 

 

 

 

 

 

Note:

* Please Strike off whichever is not applicable

This sheet is to be filled separately for each reference plant.

SCHEDULE-4(iii)

(SELECTIVE CATALYTIC REDUCTION (SCR) SYSTEM)

(Furnish detail of all pulverised coal fired units where SCR system retrofitted by

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 26

you)

Detail of plants executed by us as retrofitting of Selective Catalytic Reduction (SCR) system for NOx emission control in a pulverised coal fired power plant which is in successful operation. The details of same are furnished below:

Sl.No.

Description

Detail

 

 

 

1.

Name of the Client

 

 

 

 

 

Client name & address

 

 

Telephone No.:

 

 

Fax No.:

 

 

E-mail address:

 

 

 

 

2.

Name & Location of Plant

 

 

 

 

3.

Offered Technology

SCR

 

 

 

4.

Unit Capacity (MW)

 

 

 

 

5.

Whether plant is pulverised coal fired

Yes

 

 

 

6.

Type of Boiler

 

 

Tower type/ two pass

 

 

Tangential fired/ Wall fired

 

7Contract No. & Date Starting date of Project

Scheduled date of Commissioning Actual date of Commissioning

Date of commencement of successful operation

8.

Scope of work executed by us for the aforesaid SCR

 

system includes the following:

 

 

a)

Designed

Yes*/No*

 

 

 

b)

Engineered

Yes*/No*

 

 

 

c)

*Manufactured/*Got manufactured

Yes*/No*

 

 

 

d)

*Erection/*Supervised

Yes*/No*

 

 

 

 

erection/**Acted as Advisor for

 

 

 

erection

 

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 27

 

e)

*Commissioned/*Supervised

Yes*/No*

 

 

 

 

 

 

commissioning/**Acted as advisor

 

 

 

 

for commissioning

 

 

 

f)

Whether the plant is in successful

Yes*/No*

 

 

 

 

 

 

operation for a period of one (1) year

 

 

 

 

(minimum) as on date of techno-

 

 

 

 

commercial bid opening

 

 

 

 

Note: In case answer is “No” in any of

 

 

 

 

the above, pl. indicate the name of

 

 

 

 

the Agency.

 

 

9.

Whether Civil, structural work for SCR system has

 

 

been executed (YES/NO)

 

 

 

 

 

 

 

10.

 

Type of coal used

 

 

 

 

i) Max. HHV (Kcal/Kg)

 

 

 

 

ii) Min. HHV (Kcal/Kg)

 

 

 

 

iii) Max. Ash content (%)

 

 

 

 

iv) Max. total moisture content (%)

 

 

 

 

v) Volatile matter content (%)

 

 

11.

Name of catalyst supplier

 

 

 

Type of catalyst ( Plate/Honeycomb/Corrugated/

 

 

other)

 

 

 

 

 

12.

No. of Air Pre heater and type of air heater i.e.

 

 

bisector/ Trisector

 

 

 

 

 

13.

Input parameters considered for SCR design

 

 

a. NOx value in mg/Nm³ on dry & 6% oxygen

 

 

 

basis

 

 

 

b. SO3 concentration

 

 

 

c. Flue gas flow rate (Nm3/s)

 

 

 

d. Inlet dust burden in g/Nm3

 

 

 

e. Temperature input range

 

 

 

f. Load range of unit considered for the NOx

 

 

 

guarantee

 

 

 

 

 

14.

Output parameters considered for SCR design

 

 

a. NOx value in mg/Nm³ on dry & 6% oxygen

 

 

 

 

 

 

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 28

 

basis

 

 

b. Noise level

 

 

c. SO2 to SO3 oxidation rate in SCR

 

 

d. SO3 concentration in flue gas at SCR outlet

 

 

e. Conversion of elemental mercury to oxidized

 

 

mercury (%) (if measured)

 

 

 

 

15.

Guaranteed parameter

 

 

a. NOx output

 

 

b. Ammonia Slip

 

 

c. SO3 conversion rate

 

 

d. Pressure drop across SCR

 

 

e. Catalyst life

 

 

 

 

16.

Detail of SCR system

 

 

 

 

 

No. of SCR reactors per boiler

 

 

 

 

 

Each SCR reactor dimension (LXWxH)(m)

 

 

 

 

 

No. of layers of catalyst

 

 

 

 

 

Provision of additional catalyst layer addition

 

 

(Specify no. of layers)

 

 

 

 

 

Volume of catalyst

 

 

 

 

 

SCR bypass for catalyst protection provided

Yes / No

 

 

 

 

Economiser bypass provided

Yes / No

 

 

 

 

Flue gas Velocity through SCR system (m/sec)

 

 

 

 

 

Weight of SCR system for structure design and

 

 

hoist capacity

 

 

Type of catalyst cleaning equipment and its

 

 

requirements

 

 

 

 

 

Catalyst erosion protection measures-Like Top

 

 

screen provided above SCR or not

 

 

 

 

 

Number of sample elements for catalyst

 

 

surveillance testing

 

 

 

 

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 29

 

Platform lay down space to accommodate catalyst

 

loading

 

 

17.

Reagent Used- Anhydrous/aqueous Ammonia/

 

urea

 

 

 

Reagent consumption rate (kg/hr)

 

 

 

Type of Control system for reagent injection

 

 

 

Space for Reagent storage & handling (m2)

 

Storage for how many days

 

 

18.

Auxiliary Power Consumption for SCR System

 

(KW)

 

 

19.

Requirement of water for SCR system

 

 

20.

Requirement of Auxiliary steam for SCR system

 

 

21.

Requirement of Compressed air

 

 

22.

Any other requirement

 

 

23.

Achieved value of NOx in Mg/Nm3

 

 

24.

Pl. indicate any major relocation or change of

 

existing equipment due to retrofitting of SCR

 

system

 

 

25.

Pl. include layout, scheme and GA drgs of

 

reference project

 

 

26.

Feedback on APH element replacement with new

 

material to cater effects of Ammonium by sulphate

 

 

27.

Schedule for completion of modification from date

 

of award

28.Unit outage/Shutdown time

29.Approximate cost of modification

Note:

* Please Strike off whichever is not applicable

This sheet is to be filled separately for each reference plant.

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 30

SCHEDULE-4(iv)

(SELECTIVE CATALYTIC REDUCTION (SCR) SYSTEM)

(Furnish detail of all pulverised coal fired units where SCR system installed by you in new installation)

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 31

Detail of plants executed by us as retrofitting of Selective Catalytic Reduction (SCR) system for NOx emission control in a pulverised coal fired power plant which is in successful operation. The details of same are furnished below:

Sl.No.

Description

 

Detail

 

 

 

 

1.

Name of the Client

 

 

 

 

 

 

 

Client name & address

 

 

 

Telephone No.:

 

 

 

Fax No.:

 

 

 

E-mail address:

 

 

 

 

 

 

2.

Name & Location of Plant

 

 

 

 

 

 

3.

Offered Technology

 

SCR

 

 

 

 

4.

Unit Capacity (MW)

 

 

 

 

 

 

5.

Whether plant is pulverised coal fired

 

Yes

 

 

 

 

6.

Type of Boiler

 

 

 

Tower type/ two pass

 

 

 

Tangential fired/ Wall fired

 

 

 

 

 

 

 

7

Contract No. & Date

 

 

 

 

 

 

Starting date of Project

 

 

 

Scheduled date of Commissioning

 

 

 

Actual date of Commissioning

 

 

 

Date of commencement of successful operation

 

 

 

 

8.

Scope of work executed by us for the aforesaid SCR

 

 

system includes the following:

 

 

 

a)

Designed

Yes*/No*

 

 

 

 

 

b)

Engineered

Yes*/No*

 

 

 

 

 

c)

*Manufactured/*Got manufactured

Yes*/No*

 

 

 

 

 

d)

*Erection/*Supervised

Yes*/No*

 

 

 

 

 

 

erection/**Acted as Advisor for

 

 

 

 

erection

 

 

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 32

 

e)

*Commissioned/*Supervised

Yes*/No*

 

 

 

 

commissioning/**Acted as advisor

 

 

 

for commissioning

 

 

f)

Whether the plant is in successful

Yes*/No*

 

 

 

 

operation for a period of one (1) year

 

 

 

(minimum) as on date of techno-

 

 

 

commercial bid opening

 

 

 

Note: In case answer is “No” in any of

 

 

 

the above, pl. indicate the name of

 

 

 

the Agency.

 

9.

Whether Civil, structural work for SCR system has

 

been executed (YES/NO)

 

 

 

 

 

10.

 

Type of coal used

 

 

 

i) Max. HHV (Kcal/Kg)

 

 

 

ii) Min. HHV (Kcal/Kg)

 

 

 

iii) Max. Ash content (%)

 

 

 

iv) Max. total moisture content (%)

 

 

 

v) Volatile matter content (%)

 

 

 

 

11.

Name of catalyst supplier

 

 

Type of catalyst ( Plate/Honeycomb/Corrugated/

 

other)

 

 

 

12.

No. of Air Pre heater and type of air heater i.e.

 

bisector/ Trisector

 

13.Input parameters considered for SCR design

a.NOx value in mg/Nm³ on dry & 6% oxygen basis

b.SO3 concentration

c.Flue gas flow rate (Nm3/s)

d.Inlet dust burden in g/Nm3

e.Temperature input range

f.Load range of unit considered for the NOx guarantee

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 33

14.

Output parameters considered for SCR design

 

 

a. NOx value in mg/Nm³ on dry & 6% oxygen

 

 

basis

 

 

b. Noise level

 

 

c. SO2 to SO3 oxidation rate in SCR

 

 

d. SO3 concentration in flue gas at SCR outlet

 

 

e. Conversion of elemental mercury to oxidized

 

 

mercury (%) (if measured)

 

 

 

 

15.

Guaranteed parameter

 

 

a. NOx output

 

 

b. Ammonia Slip

 

 

c. SO3 conversion rate

 

 

d. Pressure drop across SCR

 

 

e. Catalyst life

 

 

 

 

16.

Detail of SCR system

 

 

 

 

 

No. of SCR reactors per boiler

 

 

 

 

 

Each SCR reactor dimension (LXWxH)(m)

 

 

 

 

 

No. of layers of catalyst

 

 

 

 

 

Provision of additional catalyst layer addition

 

 

(Specify no. of layers)

 

 

 

 

 

Volume of catalyst

 

 

 

 

 

SCR bypass for catalyst protection provided

Yes / No

 

 

 

 

Economiser bypass provided

Yes / No

 

 

 

 

Flue gas Velocity through SCR system (m/sec)

 

 

 

 

 

Weight of SCR system for structure design and

 

 

hoist capacity

 

 

Type of catalyst cleaning equipment and its

 

 

requirements

 

 

 

 

 

Catalyst erosion protection measures-Like Top

 

 

screen provided above SCR or not

 

 

 

 

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 34

 

Number of sample elements for catalyst

 

surveillance testing

 

 

 

Platform lay down space to accommodate catalyst

 

loading

 

 

17.

Reagent Used- Anhydrous/aqueous Ammonia/

 

urea

 

 

 

Reagent consumption rate (kg/hr)

 

 

 

Type of Control system for reagent injection

 

 

 

Space for Reagent storage & handling (m2)

 

Storage for how many days

 

 

18.

Auxiliary Power Consumption for SCR System

 

(KW)

 

 

19.

Requirement of water for SCR system

 

 

20.

Requirement of Auxiliary steam for SCR system

 

 

21.

Requirement of Compressed air

 

 

22.

Any other requirement

 

 

23.

Achieved value of NOx in Mg/Nm3

 

 

24.

Pl. indicate any major relocation or change of

 

existing equipment due to retrofitting of SCR

 

system

 

 

25.

Pl. include layout, scheme and GA drgs of

 

reference project

 

 

26.

Feedback on APH element replacement with new

 

material to cater effects of Ammonium by sulphate

 

 

27.

Schedule for completion of modification from date

 

of award

 

 

28.

Unit outage/Shutdown time

29.Approximate cost of modification

Note:

* Please Strike off whichever is not applicable

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 35

This sheet is to be filled separately for each reference plant.

SCHEDULE-4(v)

(SELECTIVE CATALYTIC REDUCTION (SCR) SYSTEM)

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 36

(Furnish detail of all pulverised coal fired units where other technological intervenes/arrangements installed by you)

Detail of plants where other technological intervenes/arrangements executed by us as new/ retrofit work for NOx emission control in a pulverised coal fired power plant which is in successful operation. The details of same are furnished below:

Sl.No.

Description

Detail

 

 

 

1.

Name of the Client

 

 

 

 

 

Client name & address

 

 

Telephone No.:

 

 

Fax No.:

 

 

E-mail address:

 

 

 

 

2.

Name & Location of Plant

 

 

 

 

3.

Offered Technology

 

 

 

 

4.

Unit Capacity (MW)

 

 

 

 

5.

Type of Boiler

 

 

Tower type/ two pass

 

 

Tangential fired/ Wall fired

 

6Contract No. & Date Starting date of Project

Scheduled date of Commissioning Actual date of Commissioning

Date of commencement of successful operation

7.Scope of work executed by us for the aforesaid technology includes the following:

a)

Designed

Yes*/No*

 

b)

Engineered

Yes*/No*

 

c)

*Manufactured/*Got manufactured

Yes*/No*

 

d)

*Erection/*Supervised

Yes*/No*

 

 

erection/**Acted as Advisor for

 

 

erection

 

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 37

e)

*Commissioned/*Supervised Yes*/No* commissioning/**Acted as advisor

for commissioning

f)

Whether the plant is in successful Yes*/No* operation for a period of one (1) year

(minimum) as on date of techno- commercial bid opening

Note: In case answer is “No” in any of the above, pl. indicate the name of the Agency.

8.Whether Civil, structural work for aforesaid technology has been executed (YES/NO)

9.

Type of coal used

i)Max. HHV (Kcal/Kg)

ii)Min. HHV (Kcal/Kg)

iii)Max. Ash content (%)

iv)Max. total moisture content (%)

v)Volatile matter content (%)

10.Input parameters considered for design

a.NOx value in mg/Nm³ on dry & 6% oxygen basis

b.SO3 concentration

c.Flue gas flow rate (Nm3/s)

d.Inlet dust burden in g/Nm3

e.Temperature input range

f.Load range of unit considered for the Nox guarantee

11.Output parameters considered for design

a.Nox value in mg/Nm³ on dry & 6% oxygen basis

b.Noise level

c.SO2 to SO3 oxidation rate

d.SO3 concentration in flue gas before and after

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 38

 

 

modification work

 

 

e. Conversion of elemental mercury to oxidized

 

 

 

mercury (%) (if measured)

 

 

 

 

12.

Guaranteed parameter

 

 

a.

Nox output

 

 

b.

SO3 conversion rate

 

 

c.

Increase in flue gas pressure drop due to

 

 

 

modification

 

 

 

 

13.

Any reagent/chemical used

 

 

 

 

 

Reagent consumption rate (kg/hr)

 

 

 

 

 

Type of Control system for reagent injection

 

 

 

 

 

Space for Reagent storage & handling (m2)

 

 

Storage for how many days

 

 

 

 

14.

Increase in Auxiliary Power Consumption due to

 

 

modification (KW)

 

 

 

 

15.

Requirement of water

 

 

 

 

16.

Requirement of Auxiliary steam

 

 

 

 

17.

Requirement of Compressed air

 

 

 

 

18.

NOx value before and after retrofit work (mg/Nm3)

 

 

 

 

19.

Any other requirement

 

 

 

 

20.

Pl. indicate any major relocation or change of

 

 

existing equipment required for modification

 

 

 

 

21.

Pl. include layout, scheme and GA drgs of

 

 

reference project

 

 

 

 

22.

Schedule for completion of modification from date

 

 

of award

 

 

 

 

23.

Unit outage/Shutdown time

 

 

 

 

24.

Approximate cost of modification

 

 

 

 

 

Note:

* Please Strike off whichever is not applicable

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 39

This sheet is to be filled separately for each reference plant.

Schedule – 5

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 40

(TECHNO-ECONOMICS FOR VARIOUS DE-NOX TECHNOLOGIES)

We hereby furnish the detail of past techno-economic considered for the selection of a particular technology. Details of past techno-economics studies including strategies, costs (Capex and Opex), time schedule, planned outage for the each of DeNOx retrofit work. Guaranteed and achieved NOx emission level alongwith its advantage and disadvantages is enclosed herewith. Further, we are also enclosing the techno- economics for usage of reagent i.e. Anhydrous/aqueous ammonia and urea for SCR. This information is only for comparison purpose and no relation with actual costing.

Schedule – 6

(PROPOSAL FOR INSTALLATION OF DEMO/ SLIP STREAM PLANT)

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 41

We are willing to install a small pilot level SCR demonstration plant by taking slip stream (around 1500 Nm3/hr) at our own expense. Information collected from this pilot plant would be useful for selection and designing of SCR System suitable for Indian coal(s).This test will be performed along with involvement of NTPC and we will share the outcomes of the test along with all data collected during the test with NTPC. Detail of this proposal is attached herewith. We request that consumable (i.e. Power, water, auxiliary steam, compressed air and Ammonia etc) required during study shall be provided by NTPC. Required quantity of same is indicated in our proposal. In case a coal fired unit is offered to us for the pilot test, we will discuss and finalise detailed test protocol with NTPC within 2 week’s time.

Proposal shall cover the following:-

1.Purpose

2.Scope of work

3.Test facility details with diagram

4.Test method

5.Erection Schedule

6.Test schedule

7.Test conditions

8.Shut down time required

9.Utility required from Employer

10.Measurement –All additional instrument required shall be arranged by Applicants

11.Collected data to be shared

12.Result

*In case applicant do not manufacturer their own catalyst then demo plant of their associate/ sub-vendor of catalyst supplier may be proposed.

Schedule – 7

(FORM FOR ACCEPTANCE OF FRAUD PREVENTION POLICY)

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 42

We have read the contents of Fraud Prevention Policy of NTPC displayed on its tender website http://www.ntpctender.com and undertake that we shall strictly abide by the provisions of Fraud Prevention Policy of NTPC.

Schedule – 8

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 43

(ANY OTHER INFORMATION)

Additional Information relevant to the work / assignment is enclosed.

EXPRESSION OF INTEREST (EOI) FOR RETROFITTING OF NOX EMISSION CONTROL SYSTEM

FOR VARIOUS NTPC PLANTS 44