SALIENT TECHNICAL FEATURES
SPECIFICATION FOR INLET AIR FILTERATION SYSTEM
Anta Gas Power Station
1.
2.
3.
4.
5.
6.
7.
High (Pulse start) set point |
: 64 mm WC |
Low (Pulse stop) set point |
: 46 mm WC |
Pulse duration |
: 100 milisec. |
Duration between consecutive pulses. |
: 30 sec |
Air flow/cartridge |
: 737 CFM (at 270 C) |
Comp air header pr. |
: 7 bar |
Comp. Air requirement for one |
: 1.88 NM3/min |
Gas Turbine |
|
8. |
Effective air flow rate through |
: 0.35 m3/sec |
|
Each cartridge |
|
9. |
Effective media velocity |
: 0.015m/sec |
10. |
Approach air velocity |
: 1.66 m/sec |
11. |
Max comp. Air temp. |
: 770 C |
12. |
Effective surface area of filter media. |
: 22.3 m2 (minimum) |
13. |
Numbers of Pleats |
: 330 ± 2 nos. |
14. |
Length of cartridge |
: 673 mm (approx.) |
15. |
Dia of cartridge |
: 324 |
16. |
Cartridge drawing |
: Attached |
17. |
No. of filter cartridges/Gas Turbines |
: 945 nos. |
18. |
No of Gas Turbine |
: 3 nos. |
19. |
Filter media |
: Impregnated filter media |
|
|
Consisting of synthetic & cellulose |
|
|
fiber of Holling Worth’s & Vouse Co. |
|
|
of USA |
20. Adhesive for bonding filter media to |
: Thixotropic type |
|
|
and plates |
|
21. Original Manufacturers of the cartridge |
: FARR, USA. Media |