SALIENT TECHNICAL FEATURES FOR EFFLUENT QUALITY MONITORING SYSTEM (EQMS) PACKAGE FOR NTPC POWER STATIONS
“Salient technical Features of the equipment/system /services covered in IFB No 40031682 is mentioned below. These Salient Technical Features are mentioned only to facilitate the prospective bidders to
EQMS Package shall comprise of following
Scope includes Supply, Installation and Commissioning of EQMS Package at 31 locations of NTPC Station
The Scope Supply of EQMS Package shall comprise of Following:
a) ANALYZERS |
|
|
1) |
pH Analyzer |
1 No. |
2) |
Conductivity Analyzer |
1 No. |
3) |
Chemical Oxygen Demand (COD) Analyzer* |
1 No. |
4) |
Biological Oxygen Demand (BOD) Analyzer* |
1 No. |
5) |
Total Suspended Solid (TSS) Analyzer |
1 No. |
6) |
Oil in Water (OIW) Analyzer |
1 No. |
Note:- * BOD & COD analysers are shown separately for the purpose of input only otherwise any of the BOD & COD analysers can be clubbed together to be provided as a single unit meeting the specifications.
b) MEASURING INSTRUMENTS IN EFFLUENT LINE / DISCHARGE / CHANNEL
1) Temperature measurement |
1 No. |
2) Flow measurement |
1 No. |
c)DATA ACQUISITION SYSTEM
Effluent Quality Monitoring System will include an advanced data acquisition system (i.e. data logger), graphic display , mini UPS as detailed out in
d)DATA COMMUNICATION SYSTEM
The communication between EQMS and CPCB server must be
e) Scope shall also includes Enclosure, Required Electrical Power Supply System, Process Connections, Piping, Instrument/ Service Air, Instrumentation Cables, Power Cables & Cable Trays