Salient Technical Features for R&M of Main Plant Turbine Generator Package, Unit
for Ramagundam Super Thermal Power Station,
“Salient Technical Features of the equipment/systems/services covered in IFB No. 40031019 dated 19.12.2014 are mentioned below. These Salient Technical Features are mentioned only to facilitate the prospective bidders to
SALIENT TECHNICAL FEATURES:
Brief Scope of work
The scope of R&M of Main Plant Turbine Generator Package, Unit
Replacement of existing HP- IP combined and LPT with new & improved design HP- IP and LPT modules retaining LPT outer casing, stop & control valves, Turbine governing system, Turbine control system, etc. In addition, the scope covers replacement / refurbishment / retrofitting / modernization of associated turbine and generator auxiliary equipments, piping, valves, Hangers & supports etc.
Major Technical Features of Steam Turbine
(a) Type
The steam turbine shall be tandem compound, single reheat, regenerative, condensing, multi cylinder design with combined HP and IP and separate LP casing(s) directly coupled with generator suitable for indoor installation.
(b) Rating
The steam turbine generator unit shall conform to the following design and duty conditions:
(i) |
Output under Turbine maximum |
: |
210 MW |
|
continuous rating (TMCR) at generator |
|
|
|
terminals |
|
|
|
|
|
|
(ii) |
Turbine throttle steam pressure |
: |
150 Kg/cm2 (abs) |
(iii) |
Turbine throttle main steam temp. |
: |
535oC |
(iv) |
HPT Exhaust Pressure |
: |
35.7 Kg/cm2 (abs) |
(v) |
Reheat steam temp. at turbine inlet |
: |
535oC |
(vi) |
Condenser pressure |
: |
76 mm Hg (abs) |
|
|
|
|
(vii) |
Turbine speed |
: |
3000 rpm |
|
|
|
|
(viii) |
Frequency variation range around rated |
: |
+ 3% to - 5% (47.5 |
|
frequency of 50 Hz |
|
Hz to 51.5 Hz) |
|
|
|
|