Anta Gas Power Station
(A Government of India Enterprise)
(Domestic Competitive Bidding)
NOTICE INVITING TENDER (NIT)
NTPC Limited
FOR
 NIT No.
1.0 
NTPC invites on-line bids from eligible Bidders for aforesaid package, as per the scope of work briefly mentioned hereinafter:
 
NIT No: 40024418
3
CUTTING & WELDING OF BOILER TUBE SPOOL PIECES & HEADERS FOR RLA STUDY OF WHRB # 1 &
Brief Details
2.0 
                    Date:30.08.2014
 Document Sale Close Date & Time
 Source of IFB/NIT
 Anta Gas Power Station
 Contract Classification
 Services
 Last Date and Time for Bid submission
 NIT Date
 Document Sale Commencement Date & Time
 30.08.2014
 40024418
 25.09.2014 15:30:00
 30.08.2014  18:19:31
 Bid Opening Date & Time
 Cost of Bidding Documents in INR
Bid Security and Integrity Pact (if applicable) shall be submitted in a sealed envelope separately offline by the stipulated bid
submission closing date and time at the address given below. Any bid without an acceptable Bid Security and Integrity Pact (if
3.0 
 EMD in INR
 Technical Opening Date & Time
 10.10.2014 15:30:00
 30.09.2014 15:30:00
 03.10.2014 15:30:00
 Pre-Bid Conference Date & Time (if any)
 0.00
 1,125.00 
 20.09.2014
logging on to the SRM Site, the bidder would require vendor code and SRM user id and password which can be obtained by
Given. or directly through the payment gateway at our SRM Site (https://etender.ntpclakshya.co.in/sap/bc/gui/sap/its/bbpstart). For
 Last Query Date (if any)
4.0 
 
applicable) shall be treated as non-responsive by the employer and shall not be opened.
filled in questionnare for issue of vendor code and SRM user id/password.
the documents as mentioned above in the form of a crossed account Payee demand draft in favour of NTPC Ltd., Payable at Not
A complete set of Bidding Documents may be downloaded by any interested Bidder on payment (non-refundable) of the cost of
allotted any vendor code are required to approach NTPC at least three working days prior to Document Sale Close date alongwith duly
submitting a questionnaire available at our SRM site as well as at NTPC tender site (www.ntpctender.com). First time users not

& 3
NAME OF WORK: CUTTING & WELDING OF BOILER TUBE SPOOL PIECES & HEADER FOR RLA STUDY OF WHRB # 1
5.0
Brief Scope of Work & other specific detail
 
3.Cutting of sample as per the instruction of EIC.
7.All joints must be proved by radiography, which is in scope of contractor.
4.Preparation of fresh spool piece, which is to be welded.
six month old.
6.Welding of tube by a suitable welding electrode.
5.Welder must be having IBR approval certificate for high pressure welding. The IBR certificate of welder should not be more than
2.Cutting of tube by grinding only.
SCOPE OF WORK
1.Marking of proper tube /header to be cut as per the instruction of EIC.
13.Cutting of boiler casing/Hand holes (wherever required) to expose the dish ends of various boiler headers for RLA and re welding 
(after grinding) of the same is also in the scope of contractor. Gas Cutting set for this purpose shall be arranged by the contractor,
10.Radiography of each joint is to be done by a radiographer having medical certificate for limited exposure to x-rays.
8.TIG welding equipments including Argon cylinders are in contractor's scope and to be brought by contractor.
9.Welder should have  medical fitness certificate to carry out the work.
15.Removal of insulation and re insulation at points of boiler casing cutting will be done by NTPC.
TERMS AND CONDITIONS
however, Oxygen and DA gas will be supplied free of cost from NTPC side.
11.Proper heat treatment of all the welded joints (if required) is to be done by contractor.
12.Heating elements for stress relieving are to be brought by the party.
charge on returnable basis.
14. Scaffolding for all abovesaid work is to be done by contractor. However, scaffolding material will be issued by NTPC free of
The contractor has to  ensure the satisfaction of Chief Inspector of Boiler regarding of welding & other repairs being done by him
8.The contractor must be an approved contractor with Chief Inspector of Boiler, Jaipur (Rajasthan) for carrying out such type of work.
under this contract in the boiler.
9.The contracor shall obtain the permission before starting the job and the approval of Chief Inspector of Boiler, Jaipur for the job
7.The spool piece/Hand hole diameter of tube/header may vary from 31.8 mm to 105 mm.
1.All the Electrodes and filler wire shall be provided by NTPC free of cost.
3.Heating elements etc. for proper heat treatment are to be arranged by contractor.
4.Grinders & grinding wheels are to be brought by contractor.
6.The total work is to be finished within 15 days from the start of s/d of WHRB.
2.Welding machine with welding lead is to be brought by contractor.
5.All arrangements & equipments for radiography of the joints are to be arranged by the contractor.
done by him under the contract.
10. Duration of contract - 01 year.
11. Defect Liability Period - Nil
12. Payment Terms: 100% after completion of work.
13: Quantities may vary (+ -) 20 %
1.0 The Bidder should have experience in carrying out cutting welding of Boiler tube spool pieces and headers for RLA study of
WHRB # 1 : DECEMBER, 2014
documents. 
Qualifying Requirements for Bidders: 
7.0
WHRB # 3 : APRIL, 2015
6.0
15. Tentative date of RLA Study
14. Contractor has to arrange his own accomodation. No accomodation will be provided by NTPC.
Prospective bidders from U.P. State are compulsorily required to provide TIN number at the time of purchase of bidding
WHRB/Boiler of minimum 40 MW and should have completed successfully the work of welding of tube/header of 30 mm to 110 mm
or similar work during last 5 years prior to the date of submission of the bid.

3.0  The bidder should have successfully completed the work similar to mentioned above meeting any one of the following criterion as
OR
i)  One contract value not less than Rs. 7.56 lakhs.
on the date of bid opening:
iii)  Three contracts of value not less than Rs. 3.78 lakhs.
NOTE
2.0  The bidder must be an approved contractor with chief Inspector of Boiler, Jaipur (Rajasthan).
lakhs.
OR
ii)  Two contracts of value not less than Rs. 4.72 lakhs.
The bidder must submit all the supporting documents like details of work order involving above mentioned work, proof of
All the documentary support shall be given by for above requirements.
4.0  The annual average turnover during the preceding 3 financial years as on the date of bid opening shall not be less than Rs. 9.45
9414070281
10.0  Address for Communication
H. S. Dilvaria
Websites: https://etender.ntpclakshya.co.in/sap/bc/gui/sap/its/bbpstart or www.ntpctender.com or www.ntpc.co.in
DGM (C&M)
completion,  audit balance sheet of last three years, VAT registration, PAN, Service tax registration etc. to establish their credential in
9.0 
8.0
Issuance of Bidding Documents to any bidder shall not construe that bidder is considered qualified.
the  line with the qualifying requirements.
NTPC reserves the right to reject any or all bids or cancel/withdraw the NIT for the subject package without assigning any
reason whatsoever and in such case no bidder/intending bidder shall have any claim arising out of such action.